To clear debris, remove the grating, twist the internal baffle tube anti-clockwise, and pull it out to access the trap.
Installing FloPlast Pipes at a Steep Gradient
FloPlast pipes can be installed at gradients up to 1:10, as high sewage flow velocities do not cause increased pipe erosion or solid deposition.
When to Use Large Inspection Chambers
The mini access chamber is suitable for depths up to 600mm. For depths up to 3m, use the large inspection chamber and apply a double-sealed cover (D931) for depths between 1.0m and 3m.
What Is a Deep Inspection Chamber?
This chamber type, with a 350mm restricted opening, can be installed up to 3m deep and is compliant for both foul and surface water drainage.
Load Capacity for FloPlast Inspection Chambers
FloPlast inspection chamber covers meet BS EN 124 requirements. The Mini Access Chamber Covers (D830, D831) and Large Inspection Covers (D930, D931, D923) have an A15 (1.5 Tonne) rating, while the D934 is rated B125 (12.5 tonne).
Cast Iron Cover and Frame (D923) Usage
The D923 Cast Iron Cover and Frame can only be used for replacements in existing builds, as new installations require screwed-down covers and frames by regulation..